38 Monitor ISM/xL™ Hardware Guide
22-0375 rev1.1
(+)12V
(-)0V
Data B
Data A
1432
1432
56
132 1432
1432
(+)12V
(-)0V
Data A
Data B
N. O.
Com.
N. C.
Com.
N. O.
Common
Common
Tamper Output
(+)5/12VDC
Green LED
Red LED
Ground 0V
black
yellow
red
green
132 1212
2
nd
Elev Data 0
N. O.
Com.
N. C.
Com.
N. O.
Common
Bypass
Fire Bypass
Common
Tamper Output
(+)5/12VDC
Green LED
Red LED
Reader 1 Data 1
Ground 0V
Reader 1 Data 0
Panic Input
1432
56
132 143213212 12
Reader 2 Data 0
Reader 2 Data 1
XXXXX
2 Elevator
Module
Self resetting
0.5A fuse.
Low Voltage
LED
Processor OK LED
(normal = slow flash)
Unlock Relay
2 LED
Auxiliary Relay 2 LED
Module Bus communications
indicator LED
Auxiliary
Relay 1 LED
Unlock Relay
1 LED
Reader
Reader
Aux
Rly 2
Aux
Rly 1
Unlock
Rly 1
Unlock
Rly 2
Not Used
Not Used
Bypass
Fire Bypass
Panic Input
Module Bus
5V 12V
Reader Voltage
Jumper
5V 12V
Reader Voltage
Jumper
P/N 650-9017
5 digit serial
number to
program in
Module
Programming
red
orange
white
green
black
READER
for
Elevator
Module’s
second
elevator
brown not used
13
2
13
2
12143
2
5
1
2
13
2
RLY1 RLY2
(+)
(-)
DATA
DATA
DATA0
DATA1
Elevator
Relay Board
Aux
12VDC
(+
)
P/N 650-9035
Cutaway view
Earth
Common
Green LED
Reader 1/2 Data 1
Reader 1/2 Data 0
Elev1/2 Data 0
Elev1/2 Data In
Bypass
Panic In
0V Neg
(-) (+)
12VDC
Ground 0V
Common
Bypass
Fire Bypass
Common
Tamper Output
Green LED
Reader 1/2 Data 1
Reader 1/2 Data 0
Panic Out
Elev 1/2 Data 0
Elev 1/2 Data 1
Elev1/2 Data In
12VDC
12VDC
Ground 0V
P/N 641-9036
121212
32
1
4
321
4
321
1
2
12
12
32
132
1
456
32
1
45
32
1
45
(-) (+)
(+) (-)
Elev1/2 Data 1
(+) 5 / 12 VDC
Spare
Common
TB1
TB10
TB4
TB9 TB7 TB3 TB2
TB13
TB14
TB11
TB12
TB16
TB15
0V Neg
0V Neg
Fire Bypass
Module Bus
connection
from the
motherboard
or paralleling
to another
Module
Power
Supply
(+) ( )
Power
Supply
(+) ( )
Relay and Isolator
board cabinet
12VDC power
supply.
Module Bus
Elevator
Module
12VDC
Power
Supply must
also be
connected to
the Elevator
Module side
of its Isolator
boards.
Elevator
Module
Elevator
side
Elevator
Module
side
Elevator
Isolator
Board
( )
Aux
12VDC
Reader cable shield. Connect
to control unit ground lug.
Elevator Isolators and Relay boards do not have a 5 digit
serial # to program in Module Programming.
Parallel connections to next Elevator Relay board(s)
Fire Bypass is not intended for
"Life/Safety" applications.
2
nd
Elev Data 1
1
st
Elev Data 0
1
st
Elev Data 1
2
nd
Elev Data In
1
st
Elev Data In
ELEVATOR MODULE and ISOLATOR BOARD (2nd elevator connected to 2 Elevator Module)
Reader Voltage
Jumper
5V 12V
Normal RS485
Second
Elevator
Connections
to 2 Elevator
Module
Reserved for a
Service LCD Keypad
Module
Waterpipe ground input when a
cabinet ground lug is not available.
If quad cable is used, use all four
wires. Terminate two wires in #1
and two wires in #2, for
convenience.
Power to next Elevator Relay board(s) in this cabinet only. NOTE: If more elevator
relay boards are added in additional expansion cabinets with their own power supply -
ALL RELAY BOARD’S POWER SUPPLY NEGATIVES MUST HAVE A COMMON
CONNECTION.
Earth Ground
Ground
Elevator Module
current draw =
180mA.
maximum.
12
Tamper
Switch
Input
RS485 Reader
Connections for
reader runs over 500
ft.
See following
“Wiegand to RS485
Interface Board”