TruPortal Software User Guide 29
Configuring Devices
16. (Optional) If an alarm light or klaxon is wired to the door, select “Door Held/Forced” from the
Aux Relay list.
17. Configure the sensor Input Types for:
Door Contact sensor
Request to Exit button or sensor
Aux input from the Extended Request to Exit or magnetic lock contact sensor
Tamper circuitry
Note: The Aux and Tamper inputs listed above do not apply to doors connected to IPSDCs.
18. Click [Accept Changes].
19. Repeat for each door.
Door Configuration Options
Normal Grant Access Time
When a valid credential is scanned by the reader, the door will be unlocked for the time selected
here.
Note: Schlage AD-400 wireless locks ignore this setting. Configure the Relatch After value
in the Schlage Utility Software instead. See the TruPortal Wireless Locks Quick
Reference for details.
Extended Grant Access Time
When a valid credential with the Use extended strike/held times option selected (as configured
on the Access Management > Persons page) is scanned by the reader, the door will be unlocked
for the Normal Grant Access Time plus the Extended Grant Access Time. This allows users
to configure the System to comply with legislation governing access by individuals with
disabilities.
Note: Schlage AD-400 wireless locks ignore this setting. Configure this feature in the Schlage
Utility Software instead. See the TruPortal Wireless Locks Quick Reference for details.
Door Held Time
When a valid credential is scanned by the reader, the door can be held open for the Normal
Grant Access Time plus the Door Held Time. An event is recorded if a door is held open longer
than that and the Door Held Open alarm option is selected.
Extended Door Held Time
When a valid credential with the Use extended strike/held times option selected (as configured
on the Access Management > Persons page) is scanned by the reader, the door can be held open
for Normal Grant Access Time plus the Extended Door Held Time. An event is recorded if a
door is held open longer than that and the Door Held Open alarm option is selected. This allows
users to configure the System to comply with legislation governing access by individuals with
disabilities.
Request to Exit Enabled
If the door is alarmed for being forced open, held open too long, and tampering, then Request to
Exit (RTE) must be used in conjunction with either a button to be pressed for exit or a reader used
for exit, or some kind of sensor that detects someone approaching the door from the inside.
Otherwise, every time someone exits, a force door alarm will be generated.