- 2 -
Figure 5: Mounting on concrete
Always use a DV1202A mounting plate. The expansion plug must
penetrate at least 50 mm into the concrete. Please follow the steps
shown in Figure 6 if you are installing the test transmitter DV1215A.
$
For the equipment to conform to CEI standard 79-2, the
DV1215A test transmitter must be installed.
Figure 6: Control and function test
Using a voltmeter, check the background signal level in the detector
to prevent nuisance alarms. Set the sensitivity to Gmax during the
test.
DV1201A DV1221A Measure
0.7 V 0 V None
1.4 V 2 V Reduce range/remove source
$
Try to remove the source of ambient noise instead of
reducing the range.
Functional testing with hand tester DV1230 ! and mechanical
tool
":
DV1201A DV1221A
Alarm in 30 sec. Alarm in 45 sec.
Alarm after 5 blows NA
Detection range (in foot):
Technical specifications:
Input power: 9-15 VDC
2 V max. ripple pp
Current consumption: Nom. 8.6 mA
Alarm output: Form C solid state relay, max. series
resistance 35 Ohm
Alarm indication: LED-ind. output 3
Sensitivity: 5 steps of 6 dB each
Range: See Table “Detection range”
Sabotage protection: Temp. 183.2 °F
drill shield,
opening/pry-off contact,
Low voltage alarm: 7.5 V
Temperature limits: -4 °F to + 131 °F
Dimensions: 3.93 x 3.15 x 1.30 inches
Colour: Grey, RAL 7035
Weight: 0.86 lb
Concrete 13.12 45.93 45.93
Steel 1/G
max
26.25 45.93 45.93
Brick 9.84 26.25 26.25
Concrete 9.84 29.53 29.53
Steel 2/G
ref
13.12 29.53 29.53
Brick 3.28 19.69 19.69
Concrete 6.56 19.69 19.69
Steel 3/G
min
6.56 19.69 19.69
Brick - 13.12 13.12
Concrete 3.28 16.40 16.40
Steel 4 3.28 16.40 16.40
Brick - 9.84 9.84
Concrete - 13.12 13.12
Steel 5 - 13.12 13.12
Brick - 6.56 6.56
Sensitivity
setting
Material Thermal
lance
Diamond
disk
Drilling