Interlogix DV1200A Series Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sensoren Interlogix DV1200A Series herunter. Interlogix DV1200A Series User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 5
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
- 1 -
DV1201A & DV1221A
Seismic Detectors Installation Manual
Figure 2: Two ways to test the seismic detectors
1/2. 12 Vdc 7. Common (C)
3. LED indication 8/9. Tamper
4. Integrator level 10. Test control
5. Normaly Closed (NC) 11. Spare
6. Normaly Open (NO)
Test disabled (ex-factory setting)
Internal test of detector’s electronics =
Position jumper between 1 and 2 .
Function test of the detector and its physical contact
with the protected object = Position connector from
test transmitter DV1215A between 2 and 3.
Connecting terminal 10 to 0 V activates both tests.
1. Cover
2. Cover screw
3. Base plate
4. Mounting holes
5. Clamp
6. Area for mounting the
DV1215A test transmitter
7. Potentiometer for adjusting
the detector’s sensitivity
8. Connection block
9. Anti-tamper micro-switch
10. Mounting plate DV1202A
11. Fixing bolt
12. Expander bolt
13. Test transmitter DV1215A
Figure 3: General characteristics of the DV1201A / DV1221A
Using the mounting plate DV1202A as a template
A. Holes for DV1201A / DV1221A
B. Hole for expansion plug or recess mounting box
C. Template and mounting holes for test transmitter DV1215A
D. Holes for accessories.
Figure 4: Mounting the detector directly on a metal surface without using a mounting plate
Figure 1: Wiring diagram
Sentrol
24-04-'02
Manual DV1201A / DV1221A
14 999-
5620
Form: Letter (bookshape)
Formaat: Letter (boekvorm)
A4
G. Manders
110-01
White paper: 70gr/m² progresso; overprint black. If P.O.D.: use 80gr/m².
Wit papier: 70gr/m² progresso; opdruk zwart. Wanneer P.O.D.: gebruik 80gr/m².
1 A 24-04-'02 10423-10424
Seitenansicht 0
1 2 3 4 5

Inhaltsverzeichnis

Seite 1 - DV1201A & DV1221A

- 1 -DV1201A & DV1221ASeismic Detectors Installation ManualFigure 2: Two ways to test the seismic detectors1/2. 12 Vdc 7. Common (C)3. LED indicat

Seite 2

- 1 -DV1201A & DV1221ASeismic Detectors Installation ManualFigure 2: Two ways to test the seismic detectors1/2. 12 VDC 7. Common (C)3. LED indicat

Seite 3 - ! and mechanical

- 2 -Figure 5: Mounting on concreteAlways use a DV1202A mounting plate. The expansion plug mustpenetrate at least 50 mm into the concrete. Please foll

Seite 4

- 3 -Figure 7: Wiring the DV1201A/DV1221A into Most Security SystemsFigure 8: Connecting the DV1201A to a Four-wire CircuitType Control in an UL Compl

Seite 5 - Figure 11

- 4 -© Sentrol is an Interlogix company. 2002. All rights reserved. 5620-1AFigure 11

Kommentare zu diesen Handbüchern

Keine Kommentare