2 Monitor xL™ Advanced Installation Guide
21-3602E rev1.5
Advanced Program Sections, Sub Program Sections and Selections
NOTE: For quick reference to locate Advanced Programming Section Selections, consult the Index at the back of this
manual.
WARNING: Access, Elevator and Suite Security selections are only available with the addition of the
“Feature Expansion Board
” to the System.
Programming selections whose boxes are grey are not available for this version.
System Global Timer Delay Codes
00: undefined;
01: 1 sec;
02: 2 sec;
03: 3 sec;
04: 5 sec;
05: 10 sec;
06: 15 sec;
07: 20 sec;
08: 30 sec;
09: 45 sec;
10: 60 sec;
11: 90 sec;
12: 2 min;
13: 3 min;
14: 5 min;
15: 10 min;
16: 15 min;
17: 20 min;
18: 30 min;
19: 45 min;
20: 60 min;
21: 90 min;
22: 2 hr;
23: 4 hr;
24: 6 hr;
25: 8 hr;
26: 10 hr;
27: 12 hr;
28: 16 hr;
29: 20 hr;
30: 1 day;
31: 1 week
Program Section: S001 (System Wide Selections)
S00100 Keypad Selections
(left to right on keypad screen) Example:
Default Name Selections Description
14
(5 min)
Burglary Siren Time
Siren Time: See Timer Delay Codes Chart 00 =
disabled to 22 = 2 hrs max.
How long a siren in the system will
sound.
(UK ACPO = 16: 15 min)
(European = 17: 20 min)
03
Number of panel
inputs
Multiply entries by four (4)
E.g. 4 X 1 = 4. Enter “1” for 4 inputs.
4 X 2 = 8. Enter “2” for 8 inputs.
4 X 3 = 12. Enter “3” for 12 inputs.
4 X 4 = 16. Enter “4” for 16 inputs.
4 X 5 = 20. Enter “5” for 20 inputs.
MONITOR Panel default = 2
For VBUS input boards connected to the
main controller VBUS port. 20 inputs
maximum. 12 on main board and 1
VBUS input boards possible.
01
Number of panel
outputs
Multiply entries by four (4)
E.g. 4 X 1 = 4. Enter “1” for 4 outputs.
4 X 2 = 8. Enter “2” for 8 outputs.
4 X 3 = 12. Enter “3” for 12 outputs.
4 X 4 = 16. Enter “4” for 16 inputs.
4 X 5 = 20. Enter “5” for 20 inputs.
4 X 6 = 24. Enter “6” for 24 inputs.
4 X 7 = 28. Enter “7” for 28 inputs.
MONITOR Panel default = 2
(UK ACPO = 3: 12 outputs)
For VBUS output boards or modem
output boards connected to the main
controller VBUS port. 26 outputs
maximum. Program for 28 outputs and
skip outputs 27 – 28. 2 relays on main
board and 2 VBUS output boards
possible or 1 VBUS output board and
one 8 output modem board. Also see
S001:06 -07.
0
Panel Type
0 = Monitor xL, 1 = MONITOR ISM, 2 = Future, 3
= Future.
1
Module Bus
(SNAPP)
Baud Rate
0 = Auto Minimum (19K2), 1 = Auto Maximum
38K4
The communications speed between the
main panel and the expansion modules.
1
Suite Security
(Condo) Baud Rate
NOTE: This feature is only
available with the addition of
the Director Software and
Feature Expansion Board.
0 = Auto Minimum (19K2), 1 = Auto Maximum
(38K4) 2 = 9600 (Auto Minimum), 3 = future.
The communications speed between the
main panel and the Suite Security
modules.
0
Fallback Users
0: No access; 1: All readable tokens; 2: All with
valid site code; 3: 10 fallback users
Specific Cards granted access if door
controller is unable to access the panel
database.
(UK ACPO = 3)
14 ·
3 ·
1 ·
·
·
·
Save S00100