4 Monitor xL™ Advanced Installation Guide
21-3602E rev1.5
S00104 Keypad Selections
(left to right on keypad screen) Example:
Default Name Selections Description
00 Confirmed Alarm Time
Out
Time table codes.
(UK ACPO = 18)
0
Maximum Number of
Alarms per Point
Arming State
0 = All, 1 = 1, 2 = 2, 3 = 3 Primarily for
European Users.
(UK ACPO = 3)
0
Menu Navigation 0 = Standard, 1 = Ok-SOFT-3, 2 = Ok-
SOFT-1, 3 = future.
0
LCD Menu Style 0 = Standard, 1 = Ok-SOFT-3, 2 = Ok-
SOFT-1, 3 = future.
0
Unconfirmed Reset
Mode
0 = None, 1 = Follow Confirm Alarm, 2 =
Include Master, 3 = future.
(no)
Confirm Reset Service
(yes) (no)
(UK ACPO = yes)
(no)
Confirm Reset Master
(yes) (no)
(no)
Confirm Reset
Challenged PIN.
(yes) (no)
(no)
Confirm Reset using
Remote
(yes) (no)
S00105 Keypad Selections (left to right on keypad screen)
Default Name Selections Description
01100
AC
Reference
Voltage
Main panel electrical mains operation.
E.g. 01100 = 110.0 Decivolts
(UK ACPO = 02200)
070
Battery
Size
Amp hours X 10
E.g. display as 7.0
(UK ACPO = 17.0)
0
AC Sync
0=60 Hz, 1=50 Hz, 2=No sync required,
3=DC supply
Synchronization with AC line to maximize internal clock
accuracy. With an unstable AC source, select "2: AC-
No Sync" ('AC failure' will be reported if the frequency
drops below 12.5 Hz). With a DC source, be sure to
disable E003 (AC Trouble) under "Equipment
Settings".
DC supply option will not detect power failure condition
and will not have a time base sync
(UK ACPO = 1)
0
AC
Brownout
Mode
0=None, 1=Local alarm, 2=Alarm+report,
3=Report only
S00106 Keypad Selections (left to right on keypad screen)
Default Name Selections Description
001
VBUS Panel Output Base
See: Main Panel Output
Examples: next
What number the outputs that will be used on
the main controller’s VBUS connection will
start at.
001
Paging Output Base
See: Main Panel Output
Examples: next
What number the outputs that will be used on
the paging system will start at.
Also see S005:08, 09
001
Output Base for:
World Wide Modem with 8 output STU
REDCARE interface or 8 output STU
REDCARE interface
STU = Subscriber Terminal Unit
See: Main Panel Output
Examples: next
What number the outputs that will be used
with the main control board output plug in
boards will start at.
(UK ACPO = 003)
00·
0
·
0
·
0
·
0
· ·
Save S00104
Seitenansicht 9