Chapter 3
Concord Express Installation Instructions 83
Wireless Touchpads
System doesnt respond to commands entered from a wireless touchpad.
1. Verify that panel loop antenna is installed up into antenna housing mounted
on top of panel cabinet.
2. Check that touchpad battery is installed.
3. Check the touchpad battery for low voltage. Replace battery, if necessary.
4. Use an RF Sniffer (60-401) to verify that touchpad is transmitting.
5. Touchpad is not learned into panel memory. Enter program mode and learn
touchpad into memory.
Touchpad reports trouble condition.
Check the touchpad battery for low voltage. Replace battery, if necessary.