P/N 466-2371 • REV C NOV12 1
Concord 4 Installation Guide
Content
Contact information 1
Description 1
Panel location 2
Power and wire length 2
Mounting the panel 3
Programming 4
Sensor group characteristics 7
Specifications 9
Regulatory information 9
Contact information
For contact information, see www.utcfireandsecurity.com
or www.interlogix.com.
For technical support, toll-free: 888.437.3287 in the US
including Alaska, Hawaii, Puerto Rico, and Canada.
Outside the tool-free area, contact your dealer.
© 2012 UTC Fire & Security Americas Corporation, Inc.
Interlogix is part of UTC Climate Controls & Security, a
unit of United Technologies Corporation. All rights
reserved.
Description
This is the Installation Guide for the following Concord 4
control panel models:
600-1021-95R Concord 4 RF
600-1022-95R Concord Express V4
600-1040 Concord Commercial V4
600-1042 Concord Hybrid
This manual provides information for installing a basic
UL Listed Fire and Security System. To modify or use for
other purposes, visit the UTC Fire & Security website for
additional instructions and training.
Table 1 below shows the standard panel capabilities.
Table 1: Panel capabilities
Capabilities
Concord Express v4
Concord 4/Concord
Commercial v4
Zones
32
96
Partitions
2
6
Bus devices
16
16
User codes
16
230
Table 2 below describes the basic panel (out-of-box)
hardware capabilities for all panels:
Table 2: Panel hardware capabilities
Pow er
Input for an AC step-down, plug-in style
transformer.
Auxiliary pow er
output
Output that supplies 9 to 14 VDC w ith up to 1
amp for bus devices and hardwired detectors,
such as smoke and motion detectors.
Bus A and B
Input and output that provides communication
betw een bus devices and the panel.
Siren driver
Output that can drive an 8-ohm load and provides
intrusion and fire alarm sounds for partition 1 (6
w atts maximum).
Tw o onboard
outputs
Can be used to activate other signaling devices
based on system events. Out 1 is a 9 to 14 VDC
source output, limited to 1.0 amp maximum. Out
2 is an open-collector output, rated up to 14 VDC,
300 mA maximum.
Microphone input
Input used for tw o-way audio w hen used in
conjunction w ith the Interrogator 200 audio
verification module.
Eight supervised
hardw ired zones
Inputs for various hardwired detectors. Zone 8
can be set up in programming to accept tw o-wire
smoke detectors. It sources 9 to 14 VDC, 90 mA
maximum.
Built-in RF
receiver
Allow s use of up to 96 or 32 319.5 MHz crystal
and/or SAW learn mode w ireless sensors and
touchpads.
Seitenansicht 0
1 2 3 4 5 6 ... 10 11

Inhaltsverzeichnis

Seite 1 - Concord 4 Installation Guide

P/N 466-2371 • REV C • NOV12 1 Concord 4 Installation Guide Content Contact information 1 Description 1 Panel location 2 Power and wire len

Seite 2 - Power and wire length

10 Concord 4 Installation Guide Table 11: SIA setting requirements Function Default setting Required setting Exit extension On On Duress code Disab

Seite 3 - Mounting the panel

Concord 4 Installation Guide 11 Note: The installer must verify the compatibility between this panel and the central station receivers being used.

Seite 4 - Programming

2 Concord 4 Installation Guide Phone line connection Allow s panel to communicate w ith central monitoring station and/or pagers. Note: The total cu

Seite 5

Concord 4 Installation Guide 3 Device Max. wire length to panel Standby mA draw Alarm mA draw Interrogator AVM 22 ga.: 110 ft. 18 ga.: 260 ft. 45 m

Seite 6

4 Concord 4 Installation Guide Grounding the panel For maximum protection from lightning strikes and transients, connect the enclosure to earth grou

Seite 7 - Sensor group characteristics

Concord 4 Installation Guide 5 Only when the display shows SYSTEM PROGRAMMING can you advance to tier 2 programming menus. Press B or # to advance

Seite 8

6 Concord 4 Installation Guide are adding (learning) into the panel memory to send a signal to the panel. 7. To add another sensor to the same s

Seite 9 - Regulatory information

Concord 4 Installation Guide 7 Sensor group characteristics Table 10 below shows what the sensors on your Concord 4 system do. Every sensor is as

Seite 10

8 Concord 4 Installation Guide Number Name Application Alarm Delay Restoral Supervisory CS report Chime (level) Active (level) 19 Delayed interior In

Seite 11

Concord 4 Installation Guide 9 Specifications Pow er requirements Class 2, 16.5 VAC, 40 VA, 60 Hz (600-1023 or 600-1024) Rechargeable battery: 12 VDC