Description
This installation instruction applies to the following models:
2202A, 2202AU, 2204A, 2204AD, 2204AU, 2205A, 2205AU,
2207A, 2207AD, 2207AU, and 2207AH.
Mounting
To mount models 2202A, 2202AU, 2204A, 2204AD, 2204AU,
2205A, 2205AU, 2207A, 2207AD, and 2207AU, do the
following:
1. Secure the switch to the floor with appropriate fasteners
(wood or masonry). Be sure to position the switch where it
will not interfere with traffic.
2. Attach the magnet on the door so that it lines up with the
switch when the door is closed. There is a 2-inch (1-inch for
AD models) make distance between the switch and magnet to
allow for door operational tolerance.
To mount model 2207AH, do the following:
1. Secure the switch to the floor with appropriate fasteners
(wood or masonry). Be sure to position the switch where it
will not interfere with traffic.
2. Attach an ohmmeter to the common and closed loop leads.
The meter should read INFINITY with the magnet away from
the switch.
3. Align the switch and magnet so the labels read in the same
direction. Contact is polarity-sensitive.
4. Bring the magnet toward the switch until the meter again
reads INFINITY. Mark this point, and position the magnet
between these two marks.
5. Attach the magnet directly to the door or with an L-bracket
(GE Part Number 1912). See Ordering information for the
model's make distance between the switch and magnet to
allow for door operational tolerance.
2200 Series Magnetic Contacts
Installation Instructions
Figure 1. A and AD models
Figure 2. AU models
g
Magnet included
part number 1958
1.50 in.
3.81cm
1.50 in.
3.81 cm
1.50 in.
3.81 cm
2.00 in.
5.08 cm
3.50 in.
8.89 cm
3.50 in.
8.89 cm
2.25 in.
5.71 cm
0.44 in.
1.10 cm
Magnet included
part number 1982
2.10 in.
5.33 cm
3.125 in.
7.94 cm
2.125 in.
5.4 cm
0.81 in.
2.06 cm
1.50 in.
3.81 cm
3.50 in.
8.89 cm
1.50 in.
3.81 cm
Figure 3. 2207AH model
Magnet included
part number 1920
Mounting Holes
0.156 in. dia.
1.00 in.
2.54 cm
2.00 in.
5.08 cm
3.00 in.
7.62 cm
0.50 in.
1.27 cm
3.50 in.
8.89 cm
1.50 in.
3.81 cm
1.50 in.
3.81 cm
SENTROL
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Installation Instructions

DescriptionThis installation instruction applies to the following models:2202A, 2202AU, 2204A, 2204AD, 2204AU, 2205A, 2205AU,2207A, 2207AD, 2207AU, an

Seite 2 - Lead functions

Tech Support: 888-437-3287www.gesecurity.com10218E / October 2004GE Security12345 SW Leveton DriveTualatin, OR 97062503-692-4052Ordering informationSp

Kommentare zu diesen Handbüchern

Keine Kommentare