2700 Series Installation Instructions
Installation
These are the installation instructions for models 2706AP,
2706AS, 2707A, and 2707AD.
2707A/2707AD: Position magnet and switch so that the labels
read in the same direction and the Sentrol S on the magnet
aligns directly with the S on the switch. The set-up gap
distance is .4" (3/8") (1.02 cm). Switches will operate at
approximately .2" (.5 cm) to .6" (1.52 cm) on closing and go
into alarm at approximately .4" (1.02 cm) to .8" (2.03 cm) on
opening. Minimum gap is .2" (.5 cm). However, environmental
conditions, such as thickness of the metal to which the switch
and magnet attach, may alter gap distance. Therefore, we
recommend the following installation method:
1. Bring the magnet toward the switch until an ohmmeter
connected to the closed loop wires reads 0 ohms. Mark
this point.
2. Now bring the magnet closer to the switch until the meter
reads infinity. Mark this point.
3. Position the magnet midpoint between the two marks.
4. Use the magnet template to mark the mounting holes.
5. Pre-drill the mounting holes.
6. If a Pry Tamper plate is required, install it under the switch
with two #6 x 3/4" flathead screws. Connect the gold and
blue painted leads to the 24-hour circuit. The pry temper
plate is required for the Certified Safe and Vault
applications.
7. If the pry tamper is not used, discard the tamper plate and
mount the switch directly to the surface. Be sure to
connect the gold and green painted leads to the 24-hour
circuit.
2706AP/2706AS: Follow steps 1 through 7 as outlined for
models 2707A/2707AD. The 2706AP/2706AS has a built-in
remote test feature which you may order either on the
protective or supervised loop. To perform remote test
operation, apply 12 V DC, 5 mA max. current, to the green
(remote test) wires. 24 V DC remote test is available on
request.
With magnet positioned correctly, the switches will trip if an
external magnet (67 gauss or greater) is used in an attempt to
defeat the switch.
Ordering information
Part # Loop type Electrical
configuration
Gap distance
(Make)*
2706AS Open or closed SPDT 0.2" to 0.6"
2706AP Open or closed SPDT 0.2" to 0.6"
2707A Open or closed SPDT 0.2" to 0.6"
2707AD Open or closed DPDT 0.2" to 0.6"
Lead Type for all models: 3' Stainless steel armored cable
*Gap distances are nominal make distance ±20%.
Form C (2747A)
Voltage: 30 V AC
Current: .25 A Max.
Power: 3.0 W Max.
P/N 11247 • REV E • 21SEP11 1
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Ordering information

2700 Series Installation Instructions Installation These are the installation instructions for models 2706AP, 2706AS, 2707A, and 2707AD. 2707A/2707AD

Seite 2 - Contact information

Wiring Figure 1: Wiring for the 2700 Series 2707ASupervised common(gold/white)Closed loop(white)Open loop(red/white)Common(silver/white)Magnetic tampe

Kommentare zu diesen Handbüchern

Keine Kommentare