ShatterPro 3 Glassbreak Detector
ShatterPro 3
Glassbreak Detector
Installation Instructions
Description
The ShatterPro 3 is an acoustic glassbreak detector designed
to detect breaking glass from framed windows in the perimeter
of a building. The detector is mounted in the building interior
and uses a power supply from a 12VDC control panel. The
detector is available in either a low-profile round housing or a
rectangular housing that connects easily to a single-gang box.
Features
The detector provides the following features:
Range up to 25 feet (7.6 m) Internal spring clip allows
optimized room size coverage.
Alarm memory After an alarm and until power is cycled,
the alarm memory can be checked with the hand-clap test.
LED indicator Red LED provides detector test and
status indication.
Tamper resistant Provides a screw that secures the cover
to the base to prevent tampering.
Hand-clap test In addition to a test mode, you can test the
detector by clapping your hands.
Optional tamper switch Sends a signal to the control
panel when the cover is removed from the base.
What You Will Need
You need the following tools and parts to install the detector:
ShatterPro 3 detector including screw to secure the cover
to the base
Screws and wall anchors
Flat-blade screwdriver
Phillips screwdriver
Sentrol 5709C hand-held tester
Selecting a Location for the Detector
The detector can be mounted on ceilings or on walls opposite
or adjacent the window to be protected. See Figure 2.
Use the following guidelines to determine the best location to
install the detector.
Mount at least 3 feet (1 m) from glass windows
being protected.
Windows must be at least 12 x 24 inches
(30.5 x 61 cm) square.
Avoid locations where lined, insulating, or sound deaden-
ing drapes are used.
Mount 12 inches (30.5 cm) away from wall corners.
Avoid locations where interior closed wooden shutters are
used.
Locate in a suitable envionment as follows:
- Temperature between 32° and 122°F (0° and 50°C)
- Humidity between 10 and 90% non-condensing
Mount the detector on a stable surface up to 25 feet (7.6 m)
from the farthest point on the glass surface. See Figure 2.
Avoid locations that expose the detector to possible false
alarm sources such as:
- Glass airlocks and vestibule areas
- Kitchens
- Residential car garages
- Small utility rooms
- Stairwells
- Bathrooms
- Small acoustically live rooms
- Air vents
Figure 1 - ShatterPro 3 Housings
Figure 2 - Mounting Locations
Ceiling
mount
Wall
mount
25' (7.6 m)
max.
25' (7.6 m)
max.
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - Glassbreak Detector

1ShatterPro 3 Glassbreak DetectorShatterPro 3Glassbreak DetectorInstallation InstructionsDescriptionThe ShatterPro 3 is an acoustic glassbreak det

Seite 2 - Installing the Detector

2ShatterPro 3 Glassbreak DetectorSelecting the Best Location forMultiple Window CoverageThe detector has a 360° coverage pattern that can be used toco

Seite 3 - Testing the Detector

3ShatterPro 3 Glassbreak DetectorTesting the DetectorTo verify detector range and operation, you need the Sentrol5709C hand-held tester.Use the follow

Seite 4 - 1030856 Rev D 12/00

4ShatterPro 3 Glassbreak DetectorrebmuNledoM noitpircseDTN2185AmroF,gnisuohralugnatcerhtiw3orPrettahSTN2185RAmroF,gnisuohdnuorhtiw3orPrettahSTN5185 hc

Kommentare zu diesen Handbüchern

Keine Kommentare