Product Summary
Each SuperBus
®
2000 8-Zone Input Module adds eight
supervised hardwire zones. Each module includes mounting
hardware and eight 2.0K ohm end-of-line (EOL) resistors.
Power for the module is provided by the panel.
Both normally open and normally closed detectors can be
wired to module inputs. Using an EOL resistor on each loop
input, the module monitors all zones and alerts the panel if
there is an open/short circuit.
Advent
®
panels can support multiple modules for up to 250
zone inputs. UltraGard
®
panels can support up to eight
modules for 64 additional zone inputs. Concord
panels can
be expanded up to 76 zone inputs.
For additional security, the plastic case includes space for
installing a magnet and reed switch that can provide tamper
protection to detect cover removal.
SuperBus 2000
vs.
SuperBus
SuperBus 2000 panels have the ability to auto-address mod-
ule unit numbers. When the panel is powered up, the panel
automatically reads the unique SuperBus 2000 device ID
number and assigns a unit number to the module. This elim-
inates manually setting DIP switches and the chance of
identical unit number conflicts.
SuperBus 2000 Panels
Advent
Concord (software versions 2.0 and later)
SuperBus panels communicate with SuperBus 2000 mod-
ules but require the module unit number to first be set man-
ually with DIP switches.
SuperBus Panels
UltraGard
Concord (software versions 1.0–1.6)
Module Components
Figure 1. Module Circuit Board Components
Table 1. Module Component Descriptions
Component Function
Unit Number DIP
Switches
Used for manually setting unit
numbers (SuperBus panels).
SuperBus 2000
Device ID Number
Label
Identifies unique device ID
number (SuperBus 2000
panels).
Software Version
Label
Identifies the installed
software version.
Green POWER
LED
Indicates module power status.
Red BUS LED Flashes to indicate normal
communication to the panel
bus.
Wiring Terminals Used for power, bus, and
hardwire zone input
connections.
SOFTWARE
VERSION LABEL
GREEN POWER
LED
UNIT NUMBER
DIP SWITCHES
WIRING
TERMINALS
9712G01A.DSF
RED BUS
STATUS LED
SUPERBUS 2000
DEVICE ID
NUMBER LABEL
8557109A.DS4
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - =,QSXW0RGXOH

16X SHU%XV=,QSXW0RGXOHITI Part No. 60-774Document Number: 466-1606 Rev. BNovember 2000Product SummaryEach SuperBus® 2000 8-Zone Input Module

Seite 2 - Installation

2Installation GuidelinesInstallation GuidelinesFor the maximum number of bus devices and touch-pads per panel see Table 2.Do not exceed the total pane

Seite 3 - Figure 5. Support Standoff

3InstallationFigure 3. Wall Mounting Hole LocationsTo Mount the Module in an Advent Cabinet1. Remove AC panel power and disconnect the backup battery(

Seite 4 - Wiring the Module

4Wiring the ModuleWiring the ModuleTo Wire the Module to a PanelOn Advent panels, the BUS 1 and BUS 2 headers must be used only for fire or burglary a

Seite 5 - (Non-SuperBus 2000 panels)

5Installing a Cover Tamper SwitchInstalling a Cover Tamper SwitchIf you are mounting the module in its own plastic and not mounting it inside a cabine

Seite 6 - Power Up and

6Power Up and Bus CommunicationPower Up and Bus CommunicationOn Concord and Advent PanelsThis section describes how to power up the panel and mod-ule

Seite 7 - Installation Instructions

7Programming and TestingProgramming and TestingRefer to the specific panel Installation Instructions for add-ing (learning) hardwire sensors into pane

Seite 8

8NoticesNoticesFCC Part 15 Information to the UserChanges or modifications not expressly approved by Interactive Technologies, Inc. can void the user’

Kommentare zu diesen Handbüchern

Keine Kommentare