Chapter 5:
62 Simon XT TableTop Control Panel Installation Manual
Table 28: Sensor tripping instructions
Open the secured door or window.
Remove the sensor cover. Apply ice in a plastic bag to the sensor
(for 10 to 15 minutes). Do not allow the sensor to get wet.
Press a wet rag or wet finger over both of the round, gold-plated
terminals on the underside of the sensor.
Unplug the CO Alarm. Plug it back in, wait 5 seconds, then press
the TEST/RESET button until the unit beeps 8 times.
Avoid the motion sensor field of view for three minutes, then enter
its view.
Rate-of-rise heat detector
Rub your hands together until warm, then place one hand on the
detector for 30 seconds.
Tap the glass twice, away from the sensor. Wait at least 30
seconds before testing again.
Press and hold the test button until the system sounds
transmission beeps.
Press and hold the appropriate help button until the light blinks
and the panel sounds for at least seven beeps.
Press and hold Lock and Unlock simultaneously for three
seconds.
Press and hold the two Emergency buttons simultaneously for
three seconds.
Simon XT TableTop
touchpad
Press the Lights off button six times in rapid succession.
3. Interior sirens sound transmission beeps, and the display identifies the tripped
sensor and the number of RF packets received. Each beep represents one
RF packet. Count the number of beeps and refer to Table 29 below for
minimum requirements. After the beeps, the panel displays Sn # Packets=XX
Name (where XX equals the number of RF packets and Name equals the
sensor name). The system will continue to prompt for sensors that have not
yet been tested. When all sensors have been tested, the panel will display Sn
test complete press Status.
Note: If a sensor does not meet the minimum transmission beep requirements,
see If a sensor fails the sensor test
Table 29: Minimum beeps
Wireless intrusion sensors