Interlogix Simon XT Installation Manual Bedienungsanleitung Seite 32

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 74
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 31
26 Simon XT Installation Manual
3. Disconnect the green and red premises phone jack wires from the Telco block
D and splice them C to the four-conductor cable A black and white (or yellow)
wires. Use weatherproof wire connectors for these splices.
4. Connect the four-conductor cable A green and red wires to the Telco block D
TIP (+) and red to RING () posts.
5. Connect the phone cord E included with the panel to the RJ31X B and the
panel LINE jack.
Figure 8: Full line seizure wiring with RJ-31X
Full line seizure wiring with one premises phone
If a single phone is all that exists on the premises, full line seizure can be
accomplished without an RJ31X (Figure 8 above).
1. Disconnect the phone from the premises phone jack and plug it into the panel
PHONE jack A. This jack is disconnected automatically whenever the panel
reports.
Seitenansicht 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 73 74

Kommentare zu diesen Handbüchern

Keine Kommentare