Appendix B: Reporting codes
68 NX-6V2 Control Panel Installation Manual
Segment 4 = Siren time (1 to 254).
Segment 5 = Telephone line cut delay (0 to 255)
Segment 6 = Cross zone time (0 to 255)
Segment 7 = Chime time in 50 mS increments (0 to
255)
Segment 8 = Dialer delay (15 to 255)
Segment 9 = Fire alarm verification time (120 to 255)
Segment 10 = Listen-in time (0 to 255)
Segment 11 = Zone monitor timer (0 to 255)
Segments 12 to 14 = Reserved
Special features
Segment 1
1 = Enable six-digit code option
2 = Require valid user code entry for *, 9, 8 and * 9, 9
functions to w ork
3 = Enable auto cancel/abort
4 = Enable w alk test mode
5 = Enable auto force-arming w ith keyfob or keyswitch
6 to 8 = Reserved
Go to program code and authorization
Segment 1
1 = Reserved
2 = Enable go to program code as an arm only code
3 = Enable go to program code as an arm only after
closing
4 = Enable go to program code as a master
arm/disarm code (can change user code)
5 = Enable go to program code as an arm/disarm
code
6 = Enable go to program code to bypass zones
7 = Enable go to program code opening and closing
reports
8 = Reserved
Segment 2
1 = Enable go to program code for partition 1
2 = Enable go to program code for partition 2
Auxiliary outputs 1 to 4 partition selection
Segment 1 = Output 1 partitions
Segment 2 = Output 2 partitions
Segment 3 = Output 3 partitions
Segment 4 = Output 4 partitions
Auxiliary outputs 1 to 4 special timing
Segments 1 to 4 (outputs 1 to 4)
1 = Aux output timed in minutes