A
bort annunciation This feature is not programmable in the panel. Flashing cancel
LED goes off when disarming.
Enabled
Cancel annunciation Cancel 23 3/6 Enabled Enabled
Duress feature Duress 44 Disabled Disabled
Two trips on cross zone 37 5/4 Disabled Required
Keypad sounds on cross
zone trip
39 5 Disabled
Cross zoning
Zone type characteristic 111 3/4 Disabled
Programmable cross zoning
time
Cross zone time 40 6 5 minutes Allowed
Swinger shutdown Swinger shutdown count 38 n/a Enabled for 1
trip
For all non fire zones. Shut down at 1 to 2 trips.
Swinger shutdown disable Swinger shutdown count 38 n/a Enabled for 1
trip
Allowed
Fire alarm verification Fire alarm verification time 40 9 Disabled Required (depends on panel and sensors)
Call waiting cancel Must be programmed as
part of the phone number
0 n/a n/a Required (depends on user phone line)
Recent closing 23 3/7 Enabled
Exit error 23 3/8 Enabled
Default changes (from prior
versions):
Power delay 40 3 60 seconds
<1> Refer to your keypad installation manual.
<2> Combined abort window time and entry delay must not exceed one minute.
10 NX-6V2 Control Panel Installation Instructions